Technical specifications |
|
Nominal flow rate |
(Qp) |
(m3/h) |
1 |
|
Maximum flow rate |
(Qs) |
(m3/h) |
2 |
|
Class of measurement accuracy |
|
|
B |
|
|
|
Metrological performance |
|
Initial flow rate |
(Qi) |
(It/h) |
8 |
|
Minimum flow rate |
(Qmin) |
(It/h) |
20 |
|
Transition flow rate |
(Qt) |
(It/h) |
80 |
|
Nominal flow rate |
(Qp) |
(m3/h) |
1 |
|
Maximum flow rate |
(Qs) |
(m3/h) |
2 |
|
Maximum water temperature |
|
(°C) |
30 |
|
Maximum recording capacity |
|
(m3) |
10.000 |
|
Test pressure |
|
(bar) |
30 |
|
Maximum working pressure |
|
(bar) |
16 |
|
Pressure loss at max. flow rate |
|
(bar) |
0,6 |
|
|
|
Size |
|
Diameter of pipe |
(D1) |
(mm) |
15 |
|
Diameter of the thread |
(D2) |
|
R 3/4" |
|
Threaded diameter of the tube |
(D3) |
|
R1/2" |
|
Length |
(L1) |
(mm) |
110 |
|
Length (with connections) |
(L2) |
(mm) |
192 |
|
Diameter of upper body |
(B) |
(mm) |
78 |
|
Heigth |
(H2) |
(mm) |
89 |
|
Heigth of the axis |
(H1) |
(mm) |
23,5 |
|
|
|
Delivery |
|
Without connections |
(kg) |
|
0,83 |
|
With connections |
(kg) |
|
1,065 |
|
Number in one packet |
|
|
10 |
|
Weight of the packet |
(kg) |
|
11,3 |
|
Size of packet |
(cm) |
|
16*42*21h |
|
|
|
Our test and calibration laboratories are checked and verified by German legal metrology Institute Eichamt Düsseldorf.
|
|