TY - 2 N 2,5 (190 mm) ( Multi jet wet type ) VELOCITY METER |
|
|
|
|
|
|
Technical specifications |
|
Nominal flow rate |
(Qp) |
(m3/h) |
2,5 |
|
Maximum flow rate |
(Qs) |
(m3/h) |
5 |
|
Class of measurement accuracy |
|
|
B |
|
|
Metrological performance |
|
Initial flow rate |
(Qi) |
(It/h) |
10 |
|
Minimum flow rate |
(Qmin) |
(It/h) |
50 |
|
Transition flow rate |
(Qt) |
(It/h) |
200 |
|
Nominal flow rate |
(QP) |
(m3/h) |
2,5 |
|
Maximum flow rate |
(Qs) |
(m3/h) |
5 |
|
Maximum water temperature |
|
(°C) |
30 |
|
Maximum recording capacity |
|
(rn3) |
100.000 |
|
Test pressure |
|
(bar) |
30 |
|
Maximum working pressure |
|
(bar) |
16 |
|
Pressure loss at max. flow rate |
|
(bar) |
0.6 |
|
|
Size |
|
Diameter of pipe |
(D1) |
(mm) |
20 |
|
Diameter of the thread |
(02) |
|
R1" |
|
Threaded diameter of the tube |
(D3) |
|
R3/4" |
|
Length |
(L1) |
(mm) |
190 |
|
Length (with connections) |
(L2) |
(mm) |
290 |
|
Diameter of upper body |
(B) |
(mm) |
85 |
|
Height |
(H2) |
(mm) |
108 |
|
Height of the axis |
(H1) |
(mm) |
34 |
|
|
Delivery |
|
Without connections |
(kg) |
|
1,43 |
|
With connections |
(kg) |
|
1,69 |
|
Number in one packet |
|
|
10 |
|
Weight of the packet |
(kg) |
|
17,8 |
|
Size of packet |
(cm) |
|
22*47*25h |
|
|
Our test and calibration laboratories are checked and verified by German legal metrology Institute Eichamt Düsseldorf.
|
|
|
|